About lab
Two-model lab for Guyton1972 Muscle Blood Flow: a core SBML simulator wired into a dedicated visualization sub-model that turns the raw state into friendly timeseries and a plain-language summary. This a model from the article: Circulation: overall regulation. It can be used to explore cardiac dynamics and compare response patterns across conditions.
Runtime
Duration600
Comms Step1
Runs
Total0
Completed0
Failed0
Metadata
Packageguyton1972-muscle-blood-flow-lab
Created2026-05-14
Updated2026-05-14
cardiovascularscenariostimulussbmlbiomodels_ebifaithfulvisualization
Manifest
{
"io": {
"inputs": [
{
"name": "integration_step",
"maps_to": "guyton1972_muscle_blood_flow_core.integration_step"
},
{
"name": "parameter_overrides",
"maps_to": "guyton1972_muscle_blood_flow_core.parameter_overrides"
},
{
"name": "initial_conditions",
"maps_to": "guyton1972_muscle_blood_flow_core.initial_conditions"
}
],
"outputs": [
{
"name": "scenario_metadata",
"maps_to": "guyton1972_muscle_blood_flow_scenario.scenario_metadata"
},
{
"name": "state",
"maps_to": "guyton1972_muscle_blood_flow_core.state"
},
{
"name": "run_summary",
"maps_to": "guyton1972_muscle_blood_flow_viz.run_summary"
}
]
},
"title": "Guyton1972 Muscle Blood Flow Lab",
"models": [
{
"path": "owned/models/guyton1972_muscle_blood_flow_scenario",
"alias": "guyton1972_muscle_blood_flow_scenario",
"parameters": {
"schedule": {
"muscle_oxygen": {
"unit": "dimensionless",
"label": "muscle oxygen",
"active": true,
"baseline": 38.0666,
"recovery": 38.0666,
"challenge": 19.0333,
"description": "Scenario-controlled muscle oxygen value."
}
},
"scenario_name": "Oxygen availability challenge",
"baseline_until": 150,
"challenge_until": 450,
"scenario_description": "Baseline is followed by a muscle oxygen challenge and recovery period."
},
"provenance": {
"owned_path": "owned/models/guyton1972_muscle_blood_flow_scenario"
}
},
{
"path": "owned/models/guyton1972_muscle_blood_flow_core",
"alias": "guyton1972_muscle_blood_flow_core",
"parameters": {
"model_path": "data/MODEL0911202318.xml",
"integration_step": 1
},
"provenance": {
"owned_path": "owned/models/guyton1972_muscle_blood_flow_core"
}
},
{
"path": "owned/models/guyton1972_muscle_blood_flow_viz",
"alias": "guyton1972_muscle_blood_flow_viz",
"parameters": {
"lab_title": "Guyton1972 Muscle Blood Flow",
"lab_question": "Does active muscle receive more blood flow?",
"integration_step": 1
},
"provenance": {
"owned_path": "owned/models/guyton1972_muscle_blood_flow_viz"
}
}
],
"wiring": [
{
"to": [
"guyton1972_muscle_blood_flow_core.muscle_oxygen"
],
"from": "guyton1972_muscle_blood_flow_scenario.muscle_oxygen"
},
{
"to": [
"guyton1972_muscle_blood_flow_viz.scenario_metadata"
],
"from": "guyton1972_muscle_blood_flow_scenario.scenario_metadata"
},
{
"to": [
"guyton1972_muscle_blood_flow_viz.state"
],
"from": "guyton1972_muscle_blood_flow_core.state"
},
{
"to": [
"guyton1972_muscle_blood_flow_viz.species_labels"
],
"from": "guyton1972_muscle_blood_flow_core.species_labels"
}
],
"runtime": {
"duration": 600,
"initial_inputs": {
"guyton1972_muscle_blood_flow_core": {
"integration_step": 1,
"initial_conditions": {
"payload": {}
},
"parameter_overrides": {
"payload": {}
}
}
},
"communication_step": 1
},
"description": "Two-model lab for Guyton1972 Muscle Blood Flow: a core SBML simulator wired into a dedicated visualization sub-model that turns the raw state into friendly timeseries and a plain-language summary. This a model from the article: Circulation: overall regulation. It can be used to explore cardiac dynamics and compare response patterns across conditions.",
"schema_version": "2.0"
}Sign in to start your own run. Public-lab history stays visible here.