About lab
Two-model lab for Guyton1972 Volume Receptors: a core SBML simulator wired into a dedicated visualization sub-model that turns the raw state into friendly timeseries and a plain-language summary. This a model from the article: Circulation: overall regulation. It can be used to explore cardiac dynamics and compare response patterns across conditions.
Runtime
Duration600
Comms Step1
Runs
Total0
Completed0
Failed0
Metadata
Packageguyton1972-volume-receptors
Created2026-05-14
Updated2026-06-13
cardiovascularscenariostimulussbmlbiomodels_ebifaithfulvisualizationother
Manifest
{
"io": {
"inputs": [
{
"name": "integration_step",
"maps_to": "guyton1972_volume_receptors_core.integration_step"
},
{
"name": "parameter_overrides",
"maps_to": "guyton1972_volume_receptors_core.parameter_overrides"
},
{
"name": "initial_conditions",
"maps_to": "guyton1972_volume_receptors_core.initial_conditions"
}
],
"outputs": [
{
"name": "scenario_metadata",
"maps_to": "guyton1972_volume_receptors_scenario.scenario_metadata"
},
{
"name": "state",
"maps_to": "guyton1972_volume_receptors_core.state"
},
{
"name": "run_summary",
"maps_to": "guyton1972_volume_receptors_viz.run_summary"
}
]
},
"title": "Guyton1972 Volume Receptors Lab",
"models": [
{
"path": "models/scenario",
"alias": "guyton1972_volume_receptors_scenario",
"parameters": {
"schedule": {
"right_atrial_pressure": {
"unit": "dimensionless",
"label": "right atrial pressure",
"active": true,
"baseline": 0.00852183,
"recovery": 0.00852183,
"challenge": 0.010226195999999998,
"description": "Scenario-controlled right atrial pressure value."
}
},
"scenario_name": "Pressure-load challenge",
"baseline_until": 150,
"challenge_until": 450,
"scenario_description": "Baseline is followed by a right atrial pressure challenge and recovery period."
}
},
{
"path": "./models/core",
"alias": "guyton1972_volume_receptors_core",
"parameters": {
"model_path": "data/MODEL0909931851.xml",
"integration_step": 1
}
},
{
"path": "./models/viz",
"alias": "guyton1972_volume_receptors_viz",
"parameters": {
"lab_title": "Guyton1972 Volume Receptors",
"lab_question": "Do volume receptors detect volume expansion?",
"integration_step": 1
}
}
],
"wiring": [
{
"to": [
"guyton1972_volume_receptors_core.right_atrial_pressure"
],
"from": "guyton1972_volume_receptors_scenario.right_atrial_pressure"
},
{
"to": [
"guyton1972_volume_receptors_viz.scenario_metadata"
],
"from": "guyton1972_volume_receptors_scenario.scenario_metadata"
},
{
"to": [
"guyton1972_volume_receptors_viz.state"
],
"from": "guyton1972_volume_receptors_core.state"
},
{
"to": [
"guyton1972_volume_receptors_viz.species_labels"
],
"from": "guyton1972_volume_receptors_core.species_labels"
}
],
"package": "guyton1972-volume-receptors",
"runtime": {
"duration": 600,
"initial_inputs": {
"guyton1972_volume_receptors_core": {
"integration_step": 1,
"initial_conditions": {
"payload": {}
},
"parameter_overrides": {
"payload": {}
}
}
},
"communication_step": 1
},
"version": "1.0.0",
"description": "Two-model lab for Guyton1972 Volume Receptors: a core SBML simulator wired into a dedicated visualization sub-model that turns the raw state into friendly timeseries and a plain-language summary. This a model from the article: Circulation: overall regulation. It can be used to explore cardiac dynamics and compare response patterns across conditions.",
"schema_version": "2.0"
}Sign in to start your own run. Public-lab history stays visible here.
Select a run from History to view its results.